Location: Chicago, Illinois
Client: Freight Distribution Center
Contract Amount: $20,000
PROBLEM
A gasoline underground storage tank pit was contaminated with dissolved gasoline analytes following removal and backfill of a 10,000 gal UST that prevented closure of the site.
SOLUTION
Sixteen (16) biosparge points were driven into groundwater through a pea gravel/colloidal clay matrix. Remtech’s native bioremediation accelerator HC-2000 was injected on a weekly basis topically and
through the sparge tips. A compact air and HC-2000 injection system was used to pulse air and enzyme into the tank pit.
At the end of a six (6) week treatment period, heterotrophic plate counts jumped to several million CFU/ml. Groundwater BETX analytes were reduced - 98% for benzene, 96% for
ethylbenzene, 99% for toluene, and 94% for total xylenes.
COST/BENEFITS
The tank pit was closed that prevented additional treatment and minimized additional facility operational interruptions.
BioSparge Injection System at Freight Terminal
BioSparge Injection Grid
BioSparge Injection Probes Driven with Electric Jackhammer